get_metrics_name called os.Hostname on every metrics call and keyed a
never-evicted cache by label values. The hostname is now resolved once
and the cache is keyed by label names, so it cannot grow with high
cardinality values. The metrics listener also honours a graceful
shutdown context.
BREAKING CHANGE: upgrades the HTTP framework from gofiber/fiber/v2 to gofiber/fiber/v3, and gofiber/websocket/v2 to gofiber/contrib/v3/websocket.
- Handlers now take fiber.Ctx (interface) instead of *fiber.Ctx. - DisableStartupMessage moved from fiber.Config to fiber.ListenConfig on the proxy/api/monitoring Listen calls. - cors AllowOrigins is now []string; c.BodyParser -> c.Bind().Body(). - app.Test takes fiber.TestConfig instead of an int timeout (tests updated). - WebSocket swapped to contrib/v3/websocket (same Conn/New/Config/IsCloseError/IsWebSocketUpgrade API; Conn.Query preserved). - Adopts fasthttp v1.71.0 (pulled by fiber v3), resolving the v1.71 Host-header enforcement that broke the prior pinned-v1.69 workaround.
fix(connpool): the background keep-alive goroutine no longer reads the mutable global cfg (captures HostGraphQL/HealthcheckGraphQL at pool creation). Under v3 timing it raced with parseConfig/test cfg reassignment; go test -race ./... is now clean (0 data races).
test: make the circuit-breaker cache-fallback and request-coalescing integration tests deterministic (cache TTL outlives the retry loop; coalescing asserts against a measured single-request baseline instead of a hard-coded count); drop the flaky timing-ratio assertion in TestTimingAttackResistance (constant-time guarantee comes from subtle.ConstantTimeCompare, not wall-clock timing).
Verified: go build, go vet, golangci-lint (0 issues), go test -race ./... (all packages pass, 0 races), govulncheck (no vulnerabilities). App + dashboard + WebSocket verified live under v3 in single-node and cluster modes.
Starting with ENABLE_CIRCUIT_BREAKER=true panicked at boot: parseConfig -> initCircuitBreaker registers a metrics gauge, but cfg.Monitoring is assigned later by StartMonitoringServer, so the registration dereferenced a nil *MetricsSetup.
Add nil-receiver guards to the MetricsSetup registration methods (RegisterMetricsGauge/GaugeFunc/Counter, RegisterFloatCounter, RegisterMetricsSummary/Histogram), matching their existing 'return a dummy to prevent panics' contract. The guard is a no-op for non-nil receivers, so existing callers are unaffected. The breaker and the admin dashboard (which reads gobreaker state directly) keep working.
Add regression tests for the nil-receiver methods and for initCircuitBreaker with nil monitoring.
* chore(security,refactor): extract sanitization and improve code quality
- [x] Extract sanitization functions to dedicated sanitization.go module
- [x] Add comprehensive golangci-lint v2 configuration with security rules
- [x] Replace interface{} with any type throughout codebase
- [x] Add admin API authentication security warning
- [x] Extract WebSocket and stats streaming constants
- [x] Add best-effort error handling comments for resource cleanup
- [x] Expand sensitive field patterns for improved PII redaction
- [x] Simplify safety checks and remove redundant nil validations
- [x] Improve test coverage for password field redaction patterns
* refactor: replace interface{} with any type alias
- [x] Replace all `map[string]interface{}` with `map[string]any`
- [x] Replace all `interface{}` with `any` in function signatures and type definitions
- [x] Update sync.Pool New function returns from `interface{}` to `any`
- [x] Add package documentation comments to 8 package files
- [x] Update type assertions and casts to work with `any` type